Still commonly used is the panned floor joist.
Using floor joist for cold air return.
Corrective measures are also suggested.
John here using the joists as a return is common practice if it is inside the envelope conditioned space.
For example an 8 by 14 inch rectangular duct will fit between 2 by 10 floor joists installed 16 inches apart on center.
If the return lies outside of the envelope insulated rigid or flex ducting is mandatory.
The photo below shows some of the joists in the vented crawl space that the basement was completely connected to.
I have a new house and have a question.
Homes with basements often use wall studs and floor joist spaces as return air cavities.
Hallways as part of a return air system.
Did that cause problems.
This article addresses the issue of unsealed wall stud cavities or panned floor joists used as a return air plenum resulting in risks such as indoor air quality issues due to negatively pressurized cavities drawing air through cracks along with any contaminants and also condensation by drawing in warm humid air.
The space between the floor joists may be used as part of the return duct system.
Using floor joists as return ducts by panning can cause leakage because negative pressure in the cavity will draw air from the outside into the cavity through the construction joints of the rim area at the end of the joist cavity.
It is impossible to create an airtight seal with this method and together with the negative pressure that is created inside the cavity air leakage occurs through joints of the rim at the end of.
As a result this panned joist return duct sucked in a lot of air from this basement when the furnace or air conditioner were running.
All my cold air returns use the space between the joists with sheet metal screwed against the joists.
All the duct work for heat uses 5 and 6 inch pipes which is fine and makes no noise.
This is an appropriate use for space that cannot be used for actual heating and air conditioning.
Most prefer rigid to flex since flex creates too much resistance and decreases airflow.
Plan your cold air return ducts to fit comfortably in this area.